﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
56	Superfluous warning for over-specific runs on clauses	phdmakk		"The issue is related to incorrect termination criteria when searching for references to component definition recursively. It can terminate prematurely if the last called function does not have a runs on clause and is the same on several levels. In the example below, if the order of f_FX and f_F0 is changed it will be fine, but not as it is.

{{{
module Issue1 {
	type component C1 {
		var integer vc_V1;
	}

	function f_F0() runs on C1 {
		vc_V1 := 1;
	}

	function f_F1() runs on C1 {
		f_F0();
		f_FX();
	}

	function f_F2() runs on C1 {
		f_F1();
		f_FX();
	}

	function f_F3() runs on C1 {
		f_F2();
	}
	
	function f_FX() {
	}
}

}}}


Original report:

We have a bug report on a possible issue regarding T3Qv2 (latest working version, T3Q v2.0.0b18) on rule ""checkNoOverSpecificRunsOnClauses""

Comparing the execution on module EUTRA_CommonFunctions_MBMS run with both T3Q and T3Qv2, there is no error message on T3Q but on T3Qv2 there is an error message that we think that should not be happening:

Validation output of C:\Users\arroyona\Documents\STF160\Trunk\ttcn\Common\EUTRA\EUTRA_CommonFunctions_MBMS.ttcn

C:\Users\arroyona\Documents\STF160\Trunk\ttcn\Common\EUTRA\EUTRA_CommonFunctions_MBMS.ttcn: 218: WARNING: Code Style: Definition for ""f_EUTRA_CellInfo_GetMBMS_NotRepCoeff"" contains an over specific runs on clause! (6.13, checkNoOverSpecificRunsOnClauses)

Where the function raising the error message is as follows:

/*

* @desc Get the notification Repetition Coeff of the cell

* @param p_CellId

* @return integer

* @status APPROVED (LTE_AR10R11)

*/

function f_EUTRA_CellInfo_GetMBMS_NotRepCoeff(EUTRA_CellId_Type p_CellId) runs on EUTRA_PTC return integer

{

var SystemInformationBlockType13_r9 v_Sib13 := f_EUTRA_CellInfo_GetSib13(p_CellId);

var MBMS_NotificationRepCoeff_Type v_MCCH_NotRepCoeff := v_Sib13.notificationConfig_r9.notificationRepetitionCoeff_r9;

var integer v_RepCoeff;

select (v_MCCH_NotRepCoeff) {

case (n2) {

v_RepCoeff:= 2;

}

case (n4) {

v_RepCoeff := 4;

}

case else {

FatalError (FILE, LINE, ""invalid value for Notification Co-eff"");

}

}

return v_RepCoeff;

}

The runs on message is necessary here as the call to function @EUTRA_CommonFunctions_MBMS.f_EUTRA_CellInfo_GetSib13' runs over component type@EUTRA_Component.EUTRA_PTC'

This can be checked using the source code of our last delivery of 17wk10, on ATS LTE_AR10R11IWD17wk10:

http://www.3gpp.org/ftp/tsg_ran/WG5Test_ex-T1/TTCN/Deliveries/TTCN3/iwd-TTCN3-B2016-06D17wk10.zip

or directly testing following file of the ATS with T3qv2:

.\iwd-TTCN3-B2016-06D17wk10\LTE_AR10R11IWD17wk10\LTE_AR10R11IWD_17wk10\Common\EUTRA\EUTRA_CommonFunctions_MBMS.ttcn

Please let us know your thoughts and in case you agree, we will wait for a fixed version of the tool.


"	defect	closed	major	v2.0.0 Series	T3Q	2.0	fixed		